ClickCease
Request Quote

Tracker Pro

Fault Location Detector

Products > Fault Location > Tracker Pro

The Tracker Pro provides a rugged portable solution to locate cable abnormalities such as neutral corrosion, bad splices, shorts or open in the cable.

With an easy to use menu-driven display, the TDR can quickly be connected to a standard PC, or Phone Via Bluetooth to download the stored TDR traces.

Its advanced features provide a unique solution to detection of both gross and subtle issues in a cable system.

We believe in providing a complete solution to our clients and the TDR compliments the other MV cable diagnostic tools, such as Tan Delta and Partial Discharge. We recommend that whenever possible and applicable, all cables should be TDR'd before performing a cable diagnostic or withstand test.

Features:

  • Adjustable down to 2nSec pulse output
  • Rugged, water proof case
  • Easy to use
  • PC, Android, and IOS connectivity via Bluetooth
  • Auto / Manual Range adjustment
  • TDR trace storage
  • Triple Independent Cursors
  • Auto fault find
  • Adjustable VOP in %, or m/uS
  • Supplied PC, Android, and IOS based Software to download and analyze TDR traces

Technical Specifications

Physical Dimensions:
9.12” x 7.56” x 4.37”
231 x 192 x 111 mm
Weight
3 lbs 10 oz / 1.6kg
Power:

Battery
Internal, rechargeable, 4200 mAh Nickel-metal-hydride battery
Charging Source
External 18 VDC transformer, 1.0A
Operating Time
Greater than 6 hours
Environmental:

Operating Temperature
0°C to 50° C / 32°F to 122°F
Typical Temperature
-15° C to +60° C / 5° F to +140° F
Storage Temperature
-20°C to +60°C / -4° F to +140° F
Humidity
95% maximum relative humidity, non-condensing
Display
7" LCD color touchscreen display (800 x 480)
Maximum Range:
15,965.18 ft @ 85% VOP
Range varies with VOP. Maximum testable cable length varies with pulse width and cable type.
Horizontal Resolution:


Up to 2,000 ft (610 m):

0.44 feet @ 99% VOP
0.38 feet @ 85% VOP
0.18 feet @ 40% VOP
Over 2,000 ft (610 m):

1 ft. (.1 m) at any VOP
Vertical Resolution:

14 bits with 193 dots displayed
Vertical Sensitivity:

Greater than 65 dB
Output Connector:

Front panel Female BNC
Input Protection:

400 volts (AC + DC) from DC to 400 Hz and decreases to 10 volts at 1 MHz
Distance Accuracy:
Accuracy will vary with cable VOP and cable type.
0.44 feet @ 99% VOP0.
38 feet @ 85% VOP0.
18 feet @ 40% VOP
Ports:
Micro USB type B
Output Pulses:
2 nsec, 5 nsec, 20 nsec, 50 nsec, 100 nsec, 500 nsec
Auto dBRL:
2 digit auto return calculation at cursor setting
Waveform Storage:
Each with full vertical resolution
Standard
60 multi-pulse waveform memory

Note: Due to continuous development, the information may change without notice.

VLF / DC
Tan Delta
TD
Partial Discharge
PD
Oil
Testing
Cable
ID
Fault
Location